Aya patarosan? Telepon kami:+86-18768103560

Leupaskeun FTTH kabel patch cord baku

SC/APCMetoda Uji Kabel Serat Optik Pra-Konektor 1 Sarat jeung harti

212

1.1

Ngaran:Pra-Connectorized Serat Optik serelek Cable

1.2 Sarat Pra-Connectorized Serat Optik serelek Cable

1.3 Syarat Struktur

Pra-Connectorized Optical Fiber Drop Cable diwangun ku kabel bubuka tipe kukupu jeung colokan konektor removable serat optik.

Nurutkeun kana klasifikasi struktur, éta bisa dibagi kana: tipe tungtung prefabricated single-tungtung jeung tipe tungtung prefabricated ganda-tungtung. Diagram skématik tina struktur dipidangkeun dina Gambar 1 sareng Gambar 2.

 

1.4 Sarat pikeun Serat Panyambung Plugs optik

1.4.1 Sarat dina Ukuran konektor Serat optik

Panjang colokan Kabel Serat Optik Pra-Connectorized (kaasup leungeun baju panyalindungan) henteu kedah langkung ageung ti 60mm, anu dipidangkeun dina Gambar 3.

Grafik antarmuka sareng ukuran anu cocog kedah nyumponan sarat IEC 61754, YD/T 1272.3-2005

 

1.4.2 Sarat pikeun tungtung beungeut Panyambung

Beungeut tungtung konektor serat optik digolongkeun kana 2 jinis ieu

a) Tipe UPC: Awak pin kalayan permukaan polishing buleud sareng ngahontal kontak fisik (UPC) disayogikeun

b) Tipe APC: Awak pin kalayan permukaan polishing buleud serong 8 derajat (APC8°) sareng fisik.

kontak kahontal Beungeut tungtung awak sisipan kedah minuhan sarat tina IEC 61754, YD/T 2152-2010.

1.4.3 Syarat Struktural pikeun Panyambungna Serat Optik

 

1: Ferrule 2.awak batin 3.awak luar 4. Cinyusu 5.Set blok sirah
6. Metal buntut cecekelan 7.kontakt crimp 8. Sarung buntut 9. Kabel FTTH

Sambungan antara colokan konektor serat optik jeung kabel ftth kudu teguh jeung dipercaya. The relay sambungan tina konektor tekanan riveting shouldact dina malapah sarta strengthening anggota kabel ftth, teu kudu nungkulan inti serat optik dina kabel ftth maksakeun stress jangka panjang.

Panyambung serat optik dipaké pikeun sambungan kabel optik kudu dibereskeun dina tungtung kabel.

Fiksasi ieu teu bisa mangaruhan rentang axial normal gerak awak pin, tapi ogé nanggung tegangan tangtu.

Nalika kabel buntut ieu subjected kana gaya narik normal teu kurang ti 9.8N, awak pin teu bisa ditarik deui pikeun mastikeun operasi normal tina konektor.

1,5 syarat kabel FTTH

bubuka kabel FTTH wajib minuhan sarat tina Q / CT 2348.

Serat optik kedah serat optik single-mode conforming kana standar ITU-T G.657A

1.6 Panjangna Pra-Connectorized Serat Optik serelek Cable

Pra-Connectorized Serat Optik serelek Cable kudu bisa dikirimkeun luyu jeung sarat tina panjangna ngaropéa, mangka dianjurkeun pikeun ngaropéa nurutkeun panjang hambalan 5m atanapi 10m, kayaning: 20 m, 25 m, 30 m, 35 m, 50m 70m 100m jsb

1.7 Syarat Lingkungan

a) Suhu operasi: -40 ℃ ~ + 70 ℃.

b) Suhu gudang: -40 ℃ ~ + 70 ℃.

c) Kalembaban relatif: ≤95%(+30℃) .

d) Tekanan Barometrik: 62kPa ~ 106kPa.

1.8 Syarat Bahan

Bahan anu dianggo kedah nyumponan sarat di handap ieu:

a) Kinerja durukan bagian-bagian plastik anu dianggo pikeun Pre-Connectorized Optical Fiber Drop

Colokan kabel SC kedah saluyu sareng katangtuan GB/T 5169.5-2008 < >, sarta lilana seuneu test nyaeta 10 detik.

b) The palapah of FTTH Cable bakal dijieun tina bahan retardant seuneu, sarta kinerja retardant seuneu na wajib minuhan sarat tina 6.4.4.3 di Q / CT 2348-2011 < >.

c) Dua anggota strengthening bakal simetris disimpen dina kabel FTTH, sarta sarat strengthening anggota wajib minuhan sarat tina 6.1.4 dina Q / CT 2348-2011.

d) Pra-Connectorized Serat Optik Serelek Cable bisa tahan kaayaan test diperlukeun, napel dipaké pikeun nyieun SC colokan teu boga pangaruh ngarugikeun kana struktur colokan, sipat fisik, kimia jeung optik na kedah cocog kabel bubuka kukupu, teu kudu ngaruksak. sipat optik kabel bubuka tungtung prefabricated bubuka.

e) Sasuai jeung standar RoHS, teu bisa ngotoran lingkungan, luyu jeung standar panyalindungan lingkungan.

f) Nalika produk rengse ruksak, komponén na teu diwenangkeun pikeun ngabalukarkeun ngarugikeun ka jalma

2 Sarat kinerja

2.1 Sarat Performance optik

Tabél 1 Sarat kinerja optik

NO

Tes

L≤20m

20m

50m

100m

a

Leungitna sisipan (1310nm)1

≤0.3dB

≤0.34dB

b

Leungitna sisipan (1550nm)2

≤0.3dB

≤0,32dB

c

Balik Loss (UPC)3

≥47dB

≥46dB

≥45dB

≥44dB

d

Balik Loss (APC)4

≥55dB

≥51dB

≥49dB

≥46dB

1Leuwih ti 200m Leungitna sisipan ( 1310nm):0.30dB + L×0.36dB/1000m2Leuwih ti 200m Leungitna sisipan ( 1550nm):0.30dB + L×0.22dB/1000m2Leuwih ti 200m Leungitna sisipan ( 1550nm):0.30dB + L×0.22dB/1000°L × 0.22dB) ≥40dB4Leuwih ti 200m Balik Loss ( APC): ≥40dB

2.2 Sarat Kinerja Lingkungan

Kabel Serelek Serat Optik Pra-Connectorized kedah nyumponan syarat uji kinerja lingkungan anu dijelaskeun dina Tabel 2 sareng syarat kinerja optik anu dijelaskeun dina Tabel 1.

Tabél 2 Sarat Kinerja Lingkungan

NO

Tes

Kaayaan tés

Sarat

Ngarobah leungitna insertion (dB)

Parobahan wangun

a

suhu luhur

+ 70 ℃ 96h Test kinerja optik

≤0.2

Henteu aya karusakan mékanis, sapertos deformasi, Retak, rélaxasi sareng fenomena sanésna

b

hawa low

-40 ℃ 96hTest kinerja optik

≤0.2

Henteu aya karusakan mékanis, sapertos deformasi, Retak, rélaxasi sareng fenomena sanésna

c

Daur suhu

( 40 ℃ ~ 70 ℃) 2121 kali siklus, 168h

≤0.2

Henteu aya karusakan mékanis, sapertos deformasi, Retak, rélaxasi sareng fenomena sanésna

d

Beueus jeung panas

+40 ℃ 95%, 96h Test kinerja optik

≤0.2

Henteu aya karusakan mékanis, sapertos deformasi, Retak, rélaxasi sareng fenomena sanésna

e

Dina cai

Suhu kamar, cai168h

≤0.2

Taya deformasi, foaming, roughness, Peeling jeung fenomena lianna
Catetan: 4.6~4.12 pikeun kaayaan jeung métode tés husus

2.3 Sarat Performance mékanis

Matuh Q / CT 2348-2011《Syarat Téknis pikeun bubuka kabel optik kukupu ku pamaké China Telecom》.Table1

Tabél 1 Sarat Mékanis Métode tés

NO

Tes

Kaayaan tés

Sarat
Ngarobah leungitna insertion (dB) Parobihan bentuk sareng standar sanés saatos tés

a

Geter

Frékuénsi: 10-55Hz; Frékuénsi sapuan: frékuénsi sapuan sakali / mnt, rentang frékuénsi 45Hz; Amplitudo: 0.75mm amplitudo tunggal; Waktos: 2 jam dina unggal arah;

≤0.2

Henteu aya karusakan mékanis, sapertos deformasi, retakan, rélaxasi, jsb

b

Leupaskeun

Jangkungna: 1.5m tina sirah sampel; Kali: 8 kali;

≤0.2

Henteu aya karusakan mékanis, sapertos deformasi, retakan, rélaxasi, jsb

c

Repeatability

Selapkeun sareng cabut: 10 kali

≤0.2

Henteu aya karusakan mékanis, sapertos deformasi, retakan, rélaxasi, jsb

 

d Daya tahan mékanis Selapkeun sareng cabut: 500 kali ≤0.2 Henteu aya karusakan mékanis, sapertos deformasi, retakan, rélaxasi, jsb
e Tensile Antara colokan jeung kabel: Beban: 50, Test kinerja optik, 10 mnt; beban: 60N, Test kinerja optik, 10 mnt; ≤0.2 Henteu aya karusakan mékanis, sapertos deformasi, retakan, rélaxasi, jsb
f Torsi beban: 50N; Laju: 10 kali / mnt; waktos: 200; ≤0.2 Henteu aya karusakan mékanis, sapertos deformasi, retakan, rélaxasi, jsb
g Nyolok, tarik gaya Alat ukur gaya; —— Taya karuksakan mékanis, kayaning deformasi, cracking, rélaxasi, jsb gaya panempatan: ≤19.6N; gaya ditarikna: ≤19.6N.
h kakuatan Tensile mékanisme konci Beurat: 40N; Waktos: 10 mnt ≤0.2 Henteu aya karusakan mékanis, sapertos deformasi, retakan, rélaxasi, jsb
i Selapkeun résistansi kacapean elastis Titik H=6.9 mmPencét jumlah kali 500 kali; ≤0.2 Taya karuksakan mékanis, inti bisa balik deui ka posisi datum aslina

2.4 Paket jeung Transportasi

Pra-Connectorized Optical Fiber Drop Cable Test métode kudu dilengkepan caps lebu. Unggal sambungan kabel bubuka tipe tungtung prefabricated kudu boga coil bungkusan bebas, diaméter coil teu kudu kirang ti 25 kali diaméter kabel buntut.

Bungkusan kedah ditandaan ku modél produk, angkatan produksi, tanggal produksi, nami produsén sareng nomer standar palaksanaan.

2.5 Panyimpenan

Pra-Connectorized Serat Optik Serelek Cable teu bisa disimpen dina hawa kabuka atawa lingkungan korosi serius keur lila, kudu disimpen dina rentang suhu gudang.


waktos pos: Apr-03-2022